Metallische Bänder
|
1mm
|
-
|
0.6mm
|
75mm
|
5m
|
Leitfähig
|
-
|
-
|
Zinn
|
-
|
+120°C
|
-
|
-30°C
|
-
|
|
0.06mm
|
Kupferband
|
0.035mm
|
25mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.08mm
|
Aluminiumband
|
0.04mm
|
50mm
|
45m
|
-
|
3,8 N/cm
|
Aluminiumfolie
|
-
|
-
|
+110°C
|
-
|
-20°C
|
-
|
||
0.065mm
|
Kupferband
|
0.035mm
|
19mm
|
33m
|
Nichtleitend
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.065mm
|
Kupferband
|
0.035mm
|
25mm
|
33m
|
Nichtleitend
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.07mm
|
Aluminiumband
|
0.03mm
|
50mm
|
45m
|
-
|
3,6 N/cm
|
Aluminiumfolie
|
-
|
-
|
+110°C
|
-
|
-20°C
|
-
|
||
0.06mm
|
Kupferband
|
0.035mm
|
10mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.06mm
|
Kupferband
|
0.035mm
|
19mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.09mm
|
Aluminiumband
|
0.05mm
|
50mm
|
50m
|
-
|
3,8 N/cm
|
Aluminiumfolie
|
-
|
-
|
+110°C
|
-
|
-20°C
|
-
|
||
0.08mm
|
Aluminiumband
|
0.03mm
|
50mm
|
50m
|
Leitfähig
|
1,2 N/cm
|
Gummi
|
-
|
18N/cm
|
+70°C
|
-
|
-25°C
|
1436
|
||
|
0.07mm
|
Kupferband
|
0.035mm
|
10mm
|
33m
|
Nichtleitend
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
Ohne
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
AT525
|
|
|
0.06mm
|
Kupferband
|
0.035mm
|
25mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
Ohne
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
AT526
|
|
0.07mm
|
Kupferband
|
0.04mm
|
9.5mm
|
16m
|
Leitfähig
|
3,8 N/cm
|
Acryl
|
Ohne
|
44N/cm
|
+155°C
|
-
|
-20°C
|
1181
|
||
0.07mm
|
Kupferband
|
0.04mm
|
6.4mm
|
16m
|
Leitfähig
|
3,8 N/cm
|
Acryl
|
Ohne
|
44N/cm
|
+155°C
|
-
|
-20°C
|
1181
|
||
0.12mm
|
Aluminiumband
|
0.08mm
|
25mm
|
55m
|
Leitfähig
|
5,1 N/cm
|
Acryl
|
-
|
5.3N/cm
|
+149°C
|
-
|
-54°C
|
425
|
||
|
0.07mm
|
Kupferband
|
0.035mm
|
8mm
|
33m
|
Leitfähig
|
5 N/cm
|
Acrylat
|
Ohne
|
40N/cm
|
+155°C
|
-
|
-25°C
|
3003308A
|
|
0.07mm
|
Kupferband
|
0.04mm
|
12.7mm
|
16m
|
Leitfähig
|
3,8 N/cm
|
Acryl
|
Ohne
|
44N/cm
|
+155°C
|
-
|
-20°C
|
1181
|
||
|
0.08mm
|
Aluminiumband
|
0.04mm
|
50mm
|
45m
|
Nichtleitend
|
3,8 N/cm
|
Acryl
|
-
|
22N/cm
|
+110°C
|
-
|
-20°C
|
AT500
|
|
|
0.07mm
|
Kupferband
|
0.05mm
|
10mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
Ohne
|
85N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
AT528
|
|
0.1mm
|
Kupferband
|
0.04mm
|
19mm
|
16m
|
Leitfähig
|
3,8 N/cm
|
Acryl
|
Ohne
|
44N/cm
|
+130°C
|
-
|
-40°C
|
1245
|